The controller does not support automatic obtaining IP addresses (DHCP). The IP address is configured in the controller settings in the Configurator.


Most likely the problem is in fluorescent lighting. The lamp gives a flicker, which is invisible to the eye but recorded by the sensor.

Spider | Sensor |
14 | black |
13 | red |
9 | blue |

Re-boot of the controller to its factory state. On the menu: Controller -> Restart -> To its factory state

Right-click the device, select edit type and check the box editable fields in the field of education. Then save and try again.

Question:
LD_ConfiguratorPro finds the connected controller Spider
I enter the admin password, but it turns out the error "Controller not found, or password is not correct!".
OS finds the controller fine, the drivers are installed.
Windows...

There are several ways to work with variables in Iridium Mobile.
1. Add to the list of devices Spider, click on it, right click and select "Edit type". Add a new field, select the type Holding Register and the address. Address variables in...

A detailed description of the Modbus Protocol can be studied via the following link.

LanDrive system consists of a Central controller and network Executive modules. Their connection is on a 5-wire bus: 2 – food 2 - information lines A and B. 1 - ground. For installation use 8-wire cable FTP twisted-pair with shield, stranded each cor...

The power supply is carried out in any stable power supply constant voltage 12 volt.

A detailed description of the RS-485 standard can be explored on the following the link.

According to the specification standard RS-485 maximum cable length twisted pair can be 1200 meters. However, given this fact, it should be noted that at such distances it is necessary to reduce the baud rate of devices on the network. Usually, even ...

Cabling at the facility is carried out in several ways.
First, from the Central controller extends the beginning of the bus and through each point where you want execution units. It is desirable to feed the cable through the ceilings, sockets, switches...

The Central controller may be located in a special shield and in any available place. Modules, depending on performance, may be located in the glasses of switches, sockets, suspended ceilings, niches or as technological in a single shield.

Not desirable, but in desperate situations, when the tire is either already paved or impossible to do without branches, every ray of the tyre must be confirmed by the resistors of the required resistance encountered in a specific beam. In the most ex...

The connection is effected by crimping the conductors of the bus special tips with the help of a specialized crimping tool. Supply terminals and the crimp tool is a Sales INSYTE Electronics.

In the system LanDrive available all currently existing methods of control systems "smart house". IR remote, keyboard control, control touch panels, computer control, remote control through Internet, control with mobile phone.

Control with IR remote controls is implemented by means of modules LD2-IR. This module is able to maintain a large number of IR commands to audio -video equipment and air conditioners. Save commands is accomplished by sending with the remote in progr...

The touch panel has a special software which creates a virtual "desktops" with virtual buttons that, when clicked there is a programmed action. The panel performs wired or wireless communication with the Central system controller transmitti...

There is significant portion of customers "smart home" that wants to control the system with a group of keys are located in one place. It is enough to set in place a group of uncommitted, or standard electrical switches connected in multiba...