Questions and answers

What are the functions of a Smart house will You get? You can learn here! www.insyte.club


What software to visualized and remote control it is possible to use it in the LanDrive?
What software to visualized and remote control it is possible to use it in the LanDrive?
General questions

These are specialized software packages for "smart home", for example, HouseBot, IMC, IridiumMobile. It is also possible to use an industrial SCADA applications, Modbus OPC server, for example Masterscada and Lectus OPC server. Delivery of ...


What are the touch pad and what's the difference?
What are the touch pad and what's the difference?
General questions

Touchpad there are different types. This embedded panel PCs with integrated touch screens, tablet laptops with touch screens, including wireless ultra-mobile laptops with touch screens, specialized touch panels for smart homes, specialized touch panels...


What needs to be done in case of detection of interference in the RS-485 network?
What needs to be done in case of detection of interference in the RS-485 network?
General questions

Interference and methods of their suppression

For operation of the unit can influence the external interference:
• interference, arising under the action of electromagnetic fields (EMI) induced on the device itself and the line connection ...


Programmable logic controller SPIDER2 has the ability to write scripts in the C programming language. How to do it? To study this question?
Programmable logic controller SPIDER2 has the ability to write scripts in the C programming language. How to do it? To study this question?
General questions

Example send data via the RS-232 interface:

"const char cmd[]={0x01,0x02,0x03,0x04};
...
...
...
pSendCom2( &cmd[0], 4, NULL, 0);"


What needs to be done in case of a wrong writing a script in C language and subsequent unresponsiveness of the controller SPIDER2?
What needs to be done in case of a wrong writing a script in C language and subsequent unresponsiveness of the controller SPIDER2?
General questions

This can happen when it is not correctly written the script in C dwell logic controller. To resolve this problem, you must perform a full reset to factory defaults:

1) remove the cover from the enclosure;

2) Hold down the reset button, then...


How organized control of led groups of the lighting?
How organized control of led groups of the lighting?
General questions

In this case, use a bunch of modules LD2-PWM, LD2-U2400D dimerous and led ballasts. These modules have analog outputs of 0-10 volts, which are connected to the inputs dimerous ballasts. An example of these ballasts can be such as the LPF-90D Mean Wel...


How to properly manage polar record?
How to properly manage polar record?
General questions

The main error in connection and control of drives requiring a change of polarity is that the polarity change at the time of movement does not activate the stop mode between transmissions, which can cause an overload on the motor modules. Correctly a...